Skip to content

Diagnostics · Printers

Foreign Object Detected — Foreign object / resin auto-level sensor (Saturn 4 Ultra, Mars 5 Ultra): cause and fix

Tilt Release stuck, cured resin under vat (Saturn 4 forums).

Updated 24/10/2026 · Data: official manufacturer spec sheets

← All faults

Elegoo Saturn 4 Ultra
Elegoo Saturn 4 UltraElegoo
Difficulty 2/5Time 15–35 minCost €0Tools IPA, lint-free cloth

Symptom

Tilt Release stuck, cured resin under vat (Saturn 4 forums).

Likely cause

Resin on force sensor, loose vat screws, bulged FEP.

Fix procedure

Remove vat, IPA on sensor, recalibrate auto-level; clean Tilt Release area before next print.

On this page (4)

User maintenance & wear parts vs manufacturer service

Routine care (user-replaceable): nozzles, PEI sheets, FEP/PFA film, PTFE tubes and cleaning per the manual. Manufacturer service recommended for mainboard, power supply, motors or heater faults under warranty (Bambu Lab, Creality, Elegoo, Anycubic, Sovol, 3DMakerpro).

If you are unsure, if your machine is under warranty, or if the error persists after basic checks, contact official support or have the manufacturer repair your device.