Skip to content

Water cooling flow error — P2: water cooling flow error (P2, P2S): cause and fix. Written for Canada, in Canadian English. A price in Canadian dollars is shown only when this site has already checked a Canadian shop; euro amounts from the English edition are not converted and are not repeated here. Shop links open .

Diagnostics · xTool · Longer · Cricut

Water cooling flow error — P2: water cooling flow error (P2, P2S): cause and fix — Canada

CO2 laser stops, flow alarm (support + forums).

Updated 24/10/2026 · Data: official manufacturer spec sheets

← All faults

xTool P2 55W CO2
xTool P2 55W CO2xTool
Difficulty 3/5Time 25–45 minCost the price on Amazon.caTools Laser coolant, syringe

Symptom

CO2 laser stops, flow alarm (support + forums).

Likely cause

Air lock in coolant, pinched silicone hose, low reservoir.

Fix procedure

Bleed air, check hoses, refill xTool coolant; verify flow > 0.8 L/min.

On this page (4)

User maintenance & wear parts vs manufacturer service

Routine maintenance and user-replaceable wear parts: lenses, filters, honeycomb bed, Air Assist, blades and cutting mats. Internal faults, laser source, mainboard or drive rollers under warranty: contact the official manufacturer service (xTool, Longer Technology or Cricut) to keep your warranty and stay safe.

If you are unsure, if your machine is under warranty, or if the error persists after basic checks, contact official support or have the manufacturer repair your device.